| Item details | ||||||||
| Item description | 3410.41.0017-EX | |||||||
| RF Protector Description | High-power/low-IM GDT hybrid technology with bias-T | |||||||
| Highlights | • Broad-band operation • Self-extinguishing SEMPER(TM) functionality • With GDT unit 9071.99.0648, 90 V • Mounting screw set 9075.99.0023 included | |||||||
| Item number | 84010601 | |||||||
| Gas Tube | included | |||||||
| Data sheet | ||||||||
| Outline drawing | ||||||||
| Related documents | ||||||||
| 2002/95/EC [RoHS] | ||||||||
| 2002/96/EC [WEEE] | no special marking needed | |||||||
| Product configuration | Jump to [Top] | |||||||
| Main Path Connector | Unprotected side | 7/16 «plug (male)» | ||||||
| Protected side | 7/16 «jack (female)» | |||||||
| Connector Port3 | TNC «jack (female)» | |||||||
| Screw mounting | Thread | M8 | ||||||
| Bracket mounting | ||||||||
| Right Angle | ||||||||
| Electrical data | Jump to [Top] | |||||||
| Impedance | 50 | |||||||
| Residual Pulse Energy | 50 | µJ | ||||||
| Current Handling 8/20 | test pulse 4 kV 1.2/50µs / 2 kA 8/20µs | 30 single / 20 multiple | kA | |||||
| Port 3 Coupling | 30 | dB | ||||||
| DC Current | ≤2 | A | ||||||
| DC Voltage | ≤48 | V | ||||||
| Range 1 | Range 2 | Frame | ||||||
| Frequency range | 800 to 2200 | MHz | ||||||
| Return loss | ≥ 19 | dB | ||||||
| Insertion loss | ≤ 0.15 | dB | ||||||
| CW power | ≤ 500 | W | ||||||
| PIM 3rd order | -150 typ. | dBc | ||||||
| Environmental and general data | Jump to [Top] | |||||||
| Operating Temp min. | -40 | °C | ||||||
| Operating Temp max. | 85 | °C | ||||||
| Storage Temp min. | -40 | °C | ||||||
| Storage Temp max. | 85 | °C | ||||||
| IP Rating | according to IEC 60529, data refer to the coupled state | IP 65 | ||||||
| Weight | 440 | g | ||||||
| Number of Matings | 500 | |||||||
| Material data | Jump to [Top] | |||||||
| 2002/95/EC [RoHS] | ||||||||
| 2002/96/EC [WEEE] | no special marking needed | |||||||
| Piece part | Base material | Plating | ||||||
| Body | Brass | |||||||
| Male contact | Copper Beryllium Alloy | Gold Plating (without Nickel underplating) | ||||||
| Female contact | Brass | Gold Plating (without Nickel underplating) | ||||||
| Tests | Jump to [Top] | |||||||
| Following tests have been passed successfully. For any details please contact your nearest HUBER+SUHNER representative. | ||||||||
| Test description | Specification / Paragraph / Method | |||||||
| Temperature Shock | MIL-STD-202, Method 107, Cond. B | |||||||
| Vibration | MIL-STD-202, Method 204, Cond. D | |||||||
| Moisture Resistance | MIL-STD-202, Method 106 | |||||||